Back to Boxabl Models
ICC-ES Evaluation Report

ESR-4725 — Boxabl Structural Insulated Panels

Complete technical specifications from the ICC-ES evaluation of Boxabl's proprietary SIP panel system. This data drives every foundation design we engineer.

Reissued May 2024Subject to renewal May 2025Report Holder: Boxabl

Panel Description

Factory-laminated sandwich panels consisting of one steel facing and one magnesium oxide panel facing with an expanded polystyrene (EPS) foam core.

Wall Panel Thickness

6 inch (152.4 mm)

Roof & Floor Panel Thickness

7.5 inch (190.5 mm)

Properties Evaluated

Structural Thermal Barrier Weather Resistive Barrier Seismic Performance

Code Compliance

2021 and 2018 International Building Code (IBC)
2021 and 2018 International Residential Code (IRC)

Panel Materials

EPS Foam Core

ASTM C578, Type I — flame-spread index ≤25, smoke-developed index ≤450 (ASTM E84)

Steel Exterior Facing

50 ksi (345 MPa) 24 ga. (0.73 mm) Steel with G60 galvanization coating and primer paint, 57" wide

MgO Interior Facing

0.236-inch (6 mm) thick magnesium oxide (MgO) board, 48" wide — ICC-ES AC386 compliant

Adhesive

Type II, Class 2 — ICC-ES AC05 compliant

Transverse Load Capacity (psf)

Panel ConfigurationL/180L/240L/360
Floor/Roof Panel, Positive Wind31.331.331.3
Floor/Roof Panel, Negative Wind86.786.763.5
Wall Panel, Positive Wind38.338.338.3
Wall Panel, Negative Wind36.636.636.6

Axial Load Capacity

2,200 plf (113.875-inch wall height)

Shearwall (Seismic A-C)

349 plf (1:1 h:w aspect ratio)

Shearwall (Seismic D-F)

127 plf (1:1 h:w aspect ratio)

Seismic Design Factors

Categories A, B, C

Response Modification (R)2
Overstrength Factor (Omega-0)2.5
Deflection Amplification (Cd)2
Max Aspect Ratio1:1

Categories D through F

Response Modification (R)6.5
Overstrength Factor (Omega-0)3
Deflection Amplification (Cd)4
Max Building Height65 ft

Fire Safety & Weather Resistance

Interior Finish / Thermal Barrier

Class A per ASTM E84 — meets IBC 2603.9, no additional thermal barrier required per IBC 2603.4

Weather Resistive Barrier

Meets IBC Section 1402.2 Exception 2 — no additional weather protection required

Why This Matters for Your Foundation

The SIP panel system's load ratings, seismic design factors, and connection details directly influence how we engineer your foundation. Our PE-stamped plans account for these manufacturer specifications to ensure your foundation properly supports the Boxabl structure under all applicable loading conditions.